Ocena rentgenowskich aparatow stomatologicznych pod katem narazenia pacjentow na promieniowanie jonizujace.

2.50
Hdl Handle:
http://hdl.handle.net/10146/618137
Title:
Ocena rentgenowskich aparatow stomatologicznych pod katem narazenia pacjentow na promieniowanie jonizujace.
Authors:
Olszewski, Jerzy; Wrzesien, Małgorzata
Other Titles:
Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation.
Abstract:
The use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes.; Seventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films.; The results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs.; The study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491-496.
Affiliation:
Nofer Institute of Occupational Medicine, Lodz, Poland
Citation:
Medycyna Pracy 2017 Jun 27;68(4):491-496.
Journal:
Medycyna Pracy
Issue Date:
27-Jun-2017
URI:
http://hdl.handle.net/10146/618137
DOI:
10.13075/mp.5893.00506
PubMed ID:
28584336
Additional Links:
http://medpr.imp.lodz.pl/Ocena-rentgenowskich-aparatow-stomatologicznych-pod-katem-narazenia-pacjentow-na-promieniowanie-jonizujace,65679,0,2.html
Type:
Article
Language:
pl
ISSN:
0465-5893
Sponsors:
Finansowanie / Funding: w ramach dotacji na działalność statutową, zadanie nr IMP 16.2 pt. „Ocena rentgenowskich aparatów stomatologicznych pod kątem narażenia pacjentów na promieniowanie jonizujące”. Kierownik zadania: dr n. med. Jerzy Olszewski.
Appears in Collections:
Articles

Full metadata record

DC FieldValue Language
dc.contributor.authorOlszewski, Jerzyen
dc.contributor.authorWrzesien, Małgorzataen
dc.date.accessioned2017-08-22T12:49:12Z-
dc.date.available2017-08-22T12:49:12Z-
dc.date.issued2017-06-27-
dc.identifier.citationMedycyna Pracy 2017 Jun 27;68(4):491-496.en
dc.identifier.issn0465-5893-
dc.identifier.pmid28584336-
dc.identifier.doi10.13075/mp.5893.00506-
dc.identifier.urihttp://hdl.handle.net/10146/618137-
dc.description.abstractThe use of X-ray in dental procedures causes exposure of the patient to ionizing radiation. This exposure depends primarily on the parameters used in tooth examination. The aim of the study was to determine the patients exposure and to assess the technical condition of X-ray tubes.en
dc.description.abstractSeventeen hundred dental offices were covered by the questionnaire survey and 740 questionnaires were sent back. Direct measurements were performed in 100 units by using the thermoluminescent detectors and X-ray films.en
dc.description.abstractThe results showed that the most commonly used exposure time is 0.22±0.16 s. The average entrance dose for the parameters used most commonly by dentists is 1.7±1.4 mGy. The average efficiency of X-ray tube estimated on the basis of exposures is 46.5±23.7 μGy/mAs.en
dc.description.abstractThe study results indicate that the vast majority of X-ray tubes meet the requirements specified in the binding regulations. Med Pr 2017;67(4):491-496.en
dc.description.sponsorshipFinansowanie / Funding: w ramach dotacji na działalność statutową, zadanie nr IMP 16.2 pt. „Ocena rentgenowskich aparatów stomatologicznych pod kątem narażenia pacjentów na promieniowanie jonizujące”. Kierownik zadania: dr n. med. Jerzy Olszewski.en
dc.languagepol-
dc.language.isoplen
dc.relation.urlhttp://medpr.imp.lodz.pl/Ocena-rentgenowskich-aparatow-stomatologicznych-pod-katem-narazenia-pacjentow-na-promieniowanie-jonizujace,65679,0,2.htmlen
dc.rightsArchived with thanks to Medycyna pracyen
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.subjectX-rayen
dc.subjectdental radiologyen
dc.subjectentrance surface dose (ESD)en
dc.subjectpatienten
dc.subjectquestionnaireen
dc.subjectthermoluminescent dosimeteren
dc.titleOcena rentgenowskich aparatow stomatologicznych pod katem narazenia pacjentow na promieniowanie jonizujace.pl
dc.title.alternativeEvaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation.en
dc.typeArticleen
dc.contributor.departmentNofer Institute of Occupational Medicine, Lodz, Polanden
dc.identifier.journalMedycyna Pracyen
This item is licensed under a Creative Commons License
Creative Commons
All Items in ECNIS-NIOM are protected by copyright, with all rights reserved, unless otherwise indicated.